Home > Products > Components > Circuit Breakers > 40.5KV 1600 amp Outdoor high-voltage SF6 circuit breaker
40.5KV 1600 amp Outdoor high-voltage SF6 circuit breaker

40.5KV 1600 amp Outdoor high-voltage SF6 circuit breaker

40.5KV 1600 amp Outdoor high-voltage SF6 circuit breaker is a three-phase AC 50HZ outdoor high-voltage switchgear suitable for the control and protection of 40.5KV transmission and transformation systems. It can also be used as a connecting circuit breaker and a combination of opening and closing devices. The LW8-40.5AG circuit breaker adopts the principle of "thermal expansion+auxiliary blowing" intelligent extinguish arcs, equipped with a CT10 spring operating mechanism. The circuit breaker complies with GB/T1984-2014 "AC High Voltage Circuit Breakers" and meets the requirements of the International Electrotechnical Commission standard IEC62271-100:2001 "High Voltage Switchgear and Control Equipment - Part 100: High Voltage AC Circuit Breakers".

Model:LW8-40.5AG/1600-31.5

Send Inquiry

Product Description

Installation Site

outdoor circuit breaker

Workshop

circuit breaker

Product show

circuit breaker

package


Overview

The LW8-40.5AG outdoor high-voltage sulfur hexafluoride circuit breaker is designed for controlling and protecting 40.5KV transmission and transformation systems in outdoor settings with a frequency of 50HZ. It can function as both a connecting circuit breaker and a device for opening and closing. This circuit breaker uses the "thermal expansion+auxiliary blowing" intelligent arc extinguishing principle and is operated by a CT10 spring mechanism. It conforms to the standards outlined in GB/T1984-2014 for AC High Voltage Circuit Breakers. It meets the criteria set by the International Electrotechnical Commission standard IEC62271-100:2001 for High Voltage Switchgear and Control Equipment - Part 100: High Voltage AC Circuit Breakers.

Service and Installation Conditions

Ambient temperature: from -30 to 40 (from-40 to +40 for the particular order).

Height above sea level: <1000m(Value over 1000m should be indicated in advance.)

Air humidity: relative humidity: < 95% daily at average  <90% monthly at average

Wind pressure: ≤700Mpa.

Sunshine intensity: 0.1 W/cm under the 0/5m/s wind velocity

Maximum temperature difference daily allowed: 25

Earthquake intensity: ≤8 degree


Main parameters

Installation digram

Hot Tags: Outdoor high-voltage SF6 circuit breaker,High-voltage outdoor circuit breaker,SF6 outdoor circuit breaker,High-voltage SF6 breaker,Outdoor high-voltage breaker,SF6 circuit breaker for outdoor use,High-voltage outdoor SF6 breaker,Outdoor high-voltage SF6 switchgear,SF6 circuit breaker for high-voltage applications,Outdoor high-voltage SF6 disconnect switch

Related Category

Send Inquiry

Please Feel free to give your inquiry in the form below. We will reply you in 24 hours.
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
Reject Accept