The 72.5KV Outdoor high-voltage SF6 open type combination electrical appliances stands out as an integrated electrical device specifically designed for high-voltage power transmission and distribution systems. Its unique composition includes circuit breakers, disconnectors, earthing switches, current transformers, voltage transformers, and surge arresters, all enclosed in a metal housing filled with sulfur hexafluoride (SF6) gas, a highly effective insulating medium.
The outdoor high-voltage SF6 open-type combined apparatus stands out as an integrated electrical device specifically designed for high-voltage power transmission and distribution systems. Its unique composition includes circuit breakers, disconnectors, earthing switches, current transformers, voltage transformers, and surge arresters, all enclosed in a metal housing filled with sulfur hexafluoride (SF6) gas, a highly effective insulating medium.
The SF6 open-type combined apparatus is designed to operate reliably in a wide range of environmental conditions, including:
- Ambient temperature: -40°C to +55°C
- Altitude: Up to 2000 meters above sea level
- Humidity: Up to 95% relative humidity
- Pollution degree: Up to Class IV according to IEC standards
- Seismic conditions: Designed to withstand seismic forces as per relevant standards
- High reliability and safety due to SF6 gas insulation
- Compact design with reduced footprint
- Easy maintenance and operation
- Long service life with minimal maintenance requirements
- Environmentally friendly as SF6 is a non-toxic, non-flammable gas with a high global warming potential (GWP)
- High resistance to environmental pollution and harsh weather conditions
- Rated voltage: Typically ranges from 72.5 kV to 550 kV
- Rated current: Varies depending on the application, typically from 1250 A to 4000 A
- Rated short-circuit breaking current: Up to 63 kA
- Rated short-time withstand current: Up to 63 kA for 3 seconds
- Rated peak withstand current: Up to 170 kA
- Circuit Breaker: Designed to interrupt fault currents and perform switching operations
- Disconnector: Used to isolate the circuit for maintenance purposes
- Earthing Switch: Provides a safe grounding point for the circuit
- Current Transformers (CTs): Used for measuring current in the circuit
- Voltage Transformers (VTs): Used for measuring voltage in the circuit
- Surge Arresters: Protect the equipment from voltage surges
- SF6 Gas System: Ensures proper insulation and arc quenching within the apparatus
- Substations for power generation, transmission, and distribution
- Industrial power systems
- Renewable energy integration (e.g., wind farms, solar parks)
- Urban and rural power distribution networks
- The installation process involves several steps:
1. Site preparation: Ensuring a level and stable foundation for the apparatus
2. Assembly: Connecting the various components according to the manufacturer's instructions
3. Gas filling: Filling the SF6 gas to the specified pressure
4. Testing: Conducting electrical and mechanical tests to ensure proper operation
5. Commissioning: Final checks and adjustments to ensure the apparatus is ready for operation
The outdoor high voltage SF6 open-type combined apparatus plays a pivotal role in modern power systems, providing not only reliable and efficient operation but also ensuring safety and environmental protection, a responsibility we take seriously.